Custom Thermoelectric - Peltier

Rectangular TECs

Rectangular TECs

Our expanding line of rectangular TECs to fit almost every application need.

  • TECs listed as "Out of Stock" are built to order. Please call for lead time.
  • Other custom sizes are available. Please email or call with your requirements.

10 Item(s)

per page

List  Grid 

Set Descending Direction
  1. picture of 05111-9K31-02CU6J1 peltier cooler shown without RTV moisture sealing

    05111-9K31-02CU6J1-S Rectangular Thermoelectric/Peltier Module RTV Sealed

    Imax (amps) Qmax (watts) Vmax (volts) dT Max (°C) A (mm) B (mm) H (mm) A (in) B (in) H (in)
    2 7.2 6.3 69 5.9 24 3 0.23 0.95 0.12
  2. picture of rectangular TEC part 06311-5L31-02CFL

    06311-5L31-02CFL Thermoelectric/Peltier Module

    Imax (amps) Qmax (watts) Vmax (volts) dT Max (°C) A (mm) B (mm) H (mm) A (in) B (in) H (in)
    2 9 7.6 67 15 30 3.8 0.59 1.18 0.15
  3. image of rectangular Peltier device part number 06311-5L31-03CFL

    06311-5L31-03CFL Thermoelectric/Peltier Module

    Imax (amps) Qmax (watts) Vmax (volts) dT Max (°C) A (mm) B (mm) H (mm) A (in) B (in) H (in)
    3 14 7.6 67 15 30 3.5 0.59 1.18 0.14
  4. picture of rectangular peltier chip part number 06311-5L31-04CGQ

    06311-5L31-04CGQ Thermoelectric/Peltier Module

    Imax (amps) Qmax (watts) Vmax (volts) dT Max (°C) A (mm) B (mm) H (mm) A (in) B (in) H (in)
    4 16.7 7.6 67 20 40 4.8 0.79 1.57 0.19
  5. picture of rectangular thermoelectric module part number 06311-5L31-05CFL

    06311-5L31-05CFL Thermoelectric/Peltier Module

    Imax (amps) Qmax (watts) Vmax (volts) dT Max (°C) A (mm) B (mm) H (mm) A (in) B (in) H (in)
    5 23.4 7.6 67 15 30 3 0.59 1.18 0.12
  6. image of peltier thermoelectric module part 06311-5L31-06CGQ

    06311-5L31-06CGQ Thermoelectric/Peltier Module

    Imax (amps) Qmax (watts) Vmax (volts) dT Max (°C) A (mm) B (mm) H (mm) A (in) B (in) H (in)
    6 25.5 7.6 67 20 40 4.3 0.79 1.57 0.17
  7. image of peltier chip part number 06311-5L31-09CGQ

    06311-5L31-09CGQ Thermoelectric/Peltier Module

    Imax (amps) Qmax (watts) Vmax (volts) dT Max (°C) A (mm) B (mm) H (mm) A (in) B (in) H (in)
    9 38.2 7.6 67 20 40 3.5 0.79 1.57 0.14
  8. picture of thermoelectric device part number 06311-5P31-15CGQ

    06311-5P31-15CGQ Thermoelectric/Peltier Module

    Imax (amps) Qmax (watts) Vmax (volts) dT Max (°C) A (mm) B (mm) H (mm) A (in) B (in) H (in)
    15 70 7.6 67 20 40 3 0.79 1.57 0.12
  9. picture of peltier cooler part number 06311-5Q31-02CDK

    06311-5Q31-02CDK Thermoelectric/Peltier Module

    Imax (amps) Qmax (watts) Vmax (volts) dT Max (°C) A (mm) B (mm) H (mm) A (in) B (in) H (in)
    2 9 7.6 67 12.3 25 3.5 0.48 0.98 0.14
  10. picture of 07911-5Q31-03CFK Rectangular peltier cooler shown without RTV moisture sealing

    07911-5Q31-03CFK Rectangular Thermoelectric/Peltier Module

    Imax (amps) Qmax (watts) Vmax (volts) dT Max (°C) A (mm) B (mm) H (mm) A (in) B (in) H (in)
    3 17.6 9.5 67 15 25 3 0.59 0.98 0.12

10 Item(s)

per page

List  Grid 

Set Descending Direction